MelPump Heat Pump Guide

MelPump: Heat Pump Guide

Your complete guide to understanding heat pumps

school What is a Heat Pump?

A heat pump is a highly efficient device that transfers heat from one place to another. Instead of generating heat directly (like a gas boiler), it moves existing heat from outside air or ground into your home.

lightbulb
Did you know? Heat pumps can produce 3-5 times more heat energy than the electrical energy they consume. This makes them one of the most efficient heating systems available.

Types of Heat Pumps

air Air Source (ASHP)

Extracts heat from outside air. Most common type, easier to install. Works even when outdoor temperature is below zero.

landscape Ground Source (GSHP)

Extracts heat from the ground via buried pipes (brine circuit). More efficient but requires more installation work.

How Does It Work?

A heat pump works like a refrigerator in reverse. Here's the simplified process:

south
1. Absorb
Refrigerant absorbs heat from outside
compress
2. Compress
Compressor increases temperature
north
3. Release
Heat released to your home
sync
4. Repeat
Cycle continues automatically
remove_circle add_circle Show more technical details

The refrigeration cycle consists of four main components:

  • Evaporator - Located in outdoor unit, absorbs heat from air/ground
  • Compressor - The heart of the system, increases refrigerant pressure and temperature
  • Condenser - Releases heat to your heating water
  • Expansion valve - Reduces pressure before the cycle repeats
warning The compressor is the most expensive component. Protecting it from frequent starts/stops (short cycling) is essential for longevity.

tune Operation Modes

Your heat pump can operate in different modes depending on current heating or cooling needs:

wb_sunny
Heating

Heat is extracted from outside and transferred into your home. Used during cold months.

ac_unit
Cooling

Cycle reverses - heat is removed from inside and released outside. Used during warm months.

shower
Hot Water

Heat pump heats domestic hot water in the storage tank. Can work alongside space heating.

pause_circle
Idle / Standby

Target temperature reached. Compressor is off, system monitors temperatures.

error Watch Out: Short Cycling

If your heat pump frequently switches between modes or turns on/off every few minutes, this is called "short cycling". It can seriously damage the compressor over time.

Healthy operation: Long, continuous cycles (30+ minutes) with gradual frequency changes. Avoid frequent compressor stops.

remove_circle add_circle What are heating zones?

Many installations have two separate heating zones that can be controlled independently:

  • Zone 1 - Usually the main heating circuit (e.g., underfloor heating or main radiators)
  • Zone 2 - Secondary circuit (e.g., upstairs radiators or a different building section)

thermometer Temperature Readings

Understanding temperature readings is key to monitoring your heat pump's performance. Here's what each measurement means:

Water temperature leaving the heat pump and going into the heating system. This is the "output" of your heat pump.

Typical values:

  • Underfloor heating: 30-40°C
  • Radiators: 45-55°C
warning Efficiency tip: Lower flow temperature = higher efficiency. Every degree lower saves energy. Use the lowest temperature that keeps your home comfortable.

Water temperature returning to the heat pump after circulating through your heating system. Should be lower than flow temperature.

What to look for: Should be 3-7°C lower than flow temperature.

The difference between flow and return temperatures. Shows how much heat is being transferred to your home.

Ideal values:

  • Underfloor heating: ~5°C
  • Radiators: 7-10°C
cancel
Problem signs:
  • ΔT too small (1-2°C): Water pump may be running too fast, or system not absorbing heat properly
  • ΔT too large (>12°C): Flow may be restricted - check for blockages, air in system, or pump issues

Outside air temperature measured by the outdoor unit. Used for weather-compensated heating curves.

lightbulb The colder it is outside, the harder the heat pump works and efficiency (COP) decreases. This is normal - extracting heat from very cold air requires more energy.

Current temperature of domestic hot water in the storage tank.

Typical settings:

  • Daily use: 45-50°C
  • Legionella prevention: 60°C+ (periodic)

Internal temperature where refrigerant releases heat to the water system. Higher values usually indicate the system is working harder.

warning Very high condensing temperatures reduce efficiency. If consistently high, check if flow temperature can be lowered.

For ground source heat pumps - temperature of fluid in the ground loop entering and leaving the heat pump.

  • Brine Inlet - Fluid returning from ground (warmer in winter)
  • Brine Outlet - Fluid going to ground (cooler after heat extracted)
error If brine inlet regularly drops below 0°C, the ground loop may be undersized or there's a problem with the collector.

settings Compressor & Frequency

The compressor is the heart of your heat pump - and also its most expensive component. Understanding how it works helps you optimize settings and extend its lifespan.

Compressor Frequency

Modern heat pumps use inverter compressors that run at variable speeds. The frequency (Hz) indicates how hard the compressor is working:

20-40 Hz

Low demand

Efficient operation, maintaining temperature

40-70 Hz

Medium demand

Normal operation, actively heating

70-120 Hz

High demand

Maximum output, cold weather or recovery

dangerous Short Cycling - The Compressor Killer

Short cycling occurs when the compressor starts and stops frequently (multiple times per hour). This is extremely harmful because:

  • Each start causes mechanical stress and electrical surge
  • Startup phase uses more energy than continuous running
  • Oil doesn't circulate properly in short cycles
  • Can lead to premature compressor failure

Solutions: Add or enlarge buffer tank, lower target temperatures, adjust heating curve, ensure system is properly sized.

Flow Rate

The flow rate (liters/minute) shows how much water circulates through the system. This is crucial for heat transfer:

Too Low

Heat pump may overheat and shut down. Poor heat distribution throughout the house.

Too High

Delta T becomes too small. Wasted pump energy without efficiency benefit.

Dropping Over Time

May indicate clogged filter, air in system, or water pump degradation.

remove_circle add_circle Other compressor-related parameters
  • Fan RPM - Speed of outdoor unit fans. Varies with heating demand and defrost needs.
  • LEV (Expansion Valve) - Controls refrigerant flow. Position changes based on operating conditions.
  • Water Pump Status - Whether internal circulation pump is running.
  • 3-Way Valve - Directs flow between heating circuit and hot water tank.

eco Efficiency & COP

What is COP?

COP (Coefficient of Performance) measures how efficient your heat pump is. It's the ratio of heat output to electrical input.

COP = Heat Output ÷ Electrical Input

Example: COP of 4 means for every 1 kWh of electricity, you get 4 kWh of heat

What Affects COP?

arrow_upward Higher COP (Better)
  • Lower flow temperatures
  • Warmer outdoor temperatures
  • Underfloor heating systems
  • Properly sized heat pump
  • Good insulation
arrow_downward Lower COP (Worse)
  • Higher flow temperatures
  • Very cold outdoor conditions
  • Frequent defrost cycles
  • Booster heater usage
  • Oversized or undersized system

Energy Consumed vs Produced

The app shows estimated input power (electricity) and output power (heat). Monitoring these helps you understand real-world efficiency:

  • Estimated Input Power - Electricity being consumed by the heat pump
  • Estimated Output Power - Heat being delivered to your home
  • Estimated COP - Real-time efficiency (Output ÷ Input)
show_chart Track your energy over time to spot trends. A sudden drop in efficiency might indicate a problem needing attention, such as low refrigerant, dirty filters, or sensor issues.

ac_unit Defrost & Booster Heaters

Defrost Mode

In cold, humid conditions, frost builds up on the outdoor unit's heat exchanger. The heat pump periodically runs defrost cycles to remove this ice.

info How Defrost Works

During defrost, the heat pump temporarily reverses - it takes heat from inside your home to melt ice on the outdoor unit. You may notice a brief drop in heating during this time. This is normal.

warning When to Be Concerned
  • Defrost cycles lasting more than 10-15 minutes
  • Defrost happening more than 2-3 times per hour in extreme cold
  • Ice that doesn't clear after defrost
  • Defrost running when outdoor temperature is above 5°C

Booster Heaters

Heat pumps include electric backup heaters for situations when the compressor alone cannot meet demand:

  • Booster Heater 1 & 2 - Electric elements in the hydrobox that help heat water
  • Immersion Heater - Electric element in the hot water tank
bolt Warning: High Energy Cost

Electric backup heaters have COP of 1 - they produce only 1 kWh of heat per 1 kWh of electricity. This is 3-5x less efficient than the heat pump compressor.

Monitor for: If booster heaters run frequently during normal weather, your system may be undersized or settings need adjustment.

Legionella Mode

Periodically heats the hot water tank to 60°C+ to kill Legionella bacteria. This often requires booster heaters since heat pumps are most efficient at lower temperatures.

shield Legionella cycles are important for health safety but are energy-intensive. Most systems run them weekly. Consider scheduling during off-peak electricity hours.

list_alt All Parameters Reference

Below is a complete list of parameters available in the app. Note that not all parameters apply to every heat pump.

info Availability depends on your specific model, installation type (air source vs ground source), and whether you have additional sensors or the WiFi adapter installed.
remove_circle add_circle Click to expand full parameter list
Parameter Description
Kompresszor Állapota Megmutatja, hogy a kompresszor jelenleg működik-e vagy tétlen
Kompresszor Frekvencia A kompresszor sebessége Hz-ben, magasabb értékek nagyobb fűtési vagy hűtési teljesítményt jelentenek
Jégmentesítési Mód Jelzi, amikor a kültéri egység olvasztja a felhalmozott jeget
Szivattyú Állapot A hőszivattyú be van-e kapcsolva vagy ki
Kiegészítő Fűtés 1 Állapota Megmutatja, hogy az első tartalék elektromos fűtés aktív-e
Kiegészítő Fűtés 2 Állapota Megmutatja, hogy a második tartalék elektromos fűtés aktív-e
Kiegészítő Fűtés 3 Állapota Megmutatja, hogy a harmadik tartalék elektromos fűtés aktív-e
Merülőfűtő Állapota Megmutatja, hogy a melegvíz tárolóban lévő elektromos fűtés aktív-e
Működési mód Aktuális mód: fűtés, hűtés vagy melegvíz termelés. Más módokat is mutathat, mint fagyvédelem vagy legionella.
Működési Mód #1 Működési mód az #1-es fűtési zónához. A legtöbb hőszivattyúban ez vagy állandó áramlás vagy kompenzációs görbe mód, de néhány modell támogat fejlett módokat, mint az auto-adaptáció.
Működési Mód #2 Működési mód a #2-es fűtési zónához. A legtöbb hőszivattyúban ez vagy állandó áramlás vagy kompenzációs görbe mód, de néhány modell támogat fejlett módokat, mint az auto-adaptáció.
Hiba Van Jelzi, hogy a rendszernek van-e aktív hibája
Hibakód Diagnosztikai kód, amely probléma esetén jelenik meg
1. Zóna Aktív Az #1-es fűtési/hűtési zóna jelenleg aktív-e
2. Zóna Aktív A #2-es fűtési/hűtési zóna jelenleg aktív-e
Áramlási sebesség A rendszeren átáramló víz mennyisége literben percenként
Ventilátor 1 Fordulat Az első kültéri egység ventilátorának sebessége
Ventilátor 2 Fordulat A második kültéri egység ventilátorának sebessége
Lev A Elektronikus expanziós szelep nyitási pozíció
Bemeneti Teljesítmény Becsült fogyasztott elektromos teljesítmény
Kimeneti Teljesítmény Becsült termelt hőenergia
COP Hatékonysági arány - hőteljesítmény osztva a villamosenergia-fogyasztással
Keringető Szivattyú 1 Állapota Megmutatja, hogy a víz keringető szivattyú működik-e
Water Pump 2 Status WaterPump2Status
Water Pump 3 Status WaterPump3Status
Water Pump 4 Status WaterPump4Status
3-Utas Szelep Állapota A vizet a fűtéshez vagy melegvíz tárolóhoz irányító szelep pozíciója
Maximális Melegvíz Hőmérséklet Maximálisan megengedett melegvíz tároló hőmérséklet beállítás
Meleg víz aktiválása Azonnali melegvíz fűtést kényszerít az ütemezéstől függetlenül
Fűtés Tiltása #1 Zóna Ha engedélyezve van, megakadályozza a fűtést az #1-es zónában
Fűtés Tiltása #2 Zóna Ha engedélyezve van, megakadályozza a fűtést a #2-es zónában
Melegvíz Fűtés Tiltása Ha engedélyezve van, megakadályozza a melegvíz fűtést
Hűtési zóna #1 tiltása Ha engedélyezve van, megakadályozza a hűtést az #1-es zónában
Hűtési zóna #2 tiltása Ha engedélyezve van, megakadályozza a hűtést a #2-es zónában
Nyaralás mód Csökkentett működési mód az energia megtakarításához nyaralás alatt
Eco HMV Energiatakarékos mód, amely lassabban melegíti a vizet alacsonyabb előremenő hőmérséklettel a jobb hatékonyság érdekében
MEL Pump App Vezérlési Mód A rendszer szerveren keresztül van-e vezérelve, csak Mitsubishi hőszivattyúk támogatják
Szerviz Kód Diagnosztikai kód, amelyet a szerviztechnikusok használnak a hőszivattyú paraméter részleteinek lekérdezésére
Beltéri Hőmérséklet #1 A #1 fűtési zóna által kiszolgált helyiségek aktuális levegőhőmérséklete
Beltéri Hőmérséklet #2 A #2 fűtési zóna által kiszolgált helyiségek aktuális levegőhőmérséklete
Kültéri Hőmérséklet A hőszivattyú közelében mért aktuális külső levegőhőmérséklet
Előremenő Hőmérséklet A hőszivattyút elhagyó és a fűtési rendszerbe belépő víz hőmérséklete
Visszatérő Hőmérséklet A fűtési rendszerből a hőszivattyúba visszatérő víz hőmérséklete
Előremenő Hőmérséklet #1 A #1 fűtési zónába táplált víz hőmérséklete
Visszatérő Hőmérséklet #1 A #1 fűtési zónából visszatérő víz hőmérséklete
Előremenő Hőmérséklet #2 A #2 fűtési zónába táplált víz hőmérséklete
Visszatérő Hőmérséklet #2 A #2 fűtési zónából visszatérő víz hőmérséklete
Termosztát Hőmérséklet #1 A #1 fűtési zónához beállított kívánt helyiséghőmérséklet
Cél Hőm. #1 A #1 zóna fűtési körének cél vízhőmérséklete
Termosztát Hőmérséklet #2 A #2 fűtési zónához beállított kívánt helyiséghőmérséklet
Cél Hőm. #2 A #2 zóna fűtési körének cél vízhőmérséklete
Delta Temp. A hőszivattyút elhagyó és oda visszatérő víz hőmérséklet-különbsége, amely megmutatja, mennyi hő kerül átadásra
HMV Hőmérséklet A tartályban tárolt használati melegvíz aktuális hőmérséklete
Kondenzációs hőm. A hőszivattyú belső hőmérséklete, ahol a hűtőközeg hőt ad át a vízrendszernek; a magasabb értékek általában alacsonyabb hatásfokot jelentenek
Cél tartályvíz-hőm. A használati melegvíz tartály kívánt hőmérséklete
Kiegészítő forrás előremenő hőm. A tartalék kazánból kilépő víz hőmérséklete
Kiegészítő forrás visszatérő hőm. A tartalék kazánba visszatérő víz hőmérséklete
Keverőtartály vízhőm. A puffer- vagy keverőtartályban lévő víz hőmérséklete
Sóloldat belépő hőmérséklete A talajkör folyadékának a hőszivattyúba belépő hőmérséklete
Sóloldat kilépő hőmérséklete A talajkör folyadékának a hőszivattyút elhagyó hőmérséklete
Folyadékvezeték Hőm. A hőszivattyú hűtőkörében áramló folyékony hűtőközeg hőmérséklete

warning Troubleshooting

Here are some common issues and what to check:

  • Check if flow temperature is appropriate for your heating system
  • Verify heating curve settings match your home's heat loss
  • Check for air in the system (radiators may need bleeding)
  • Ensure all zone valves are opening correctly
  • Check if heat pump is undersized for your home
  • Check how often booster heaters are running - they use a lot of electricity
  • Review COP values - if consistently below 2.5, investigate
  • Look for excessive defrost cycles
  • Consider if flow temperatures can be reduced
  • Check Legionella cycle frequency and timing
  • This is short cycling - needs attention to protect compressor
  • Consider adding or enlarging buffer tank
  • Reduce target temperatures or adjust heating curve
  • Check if system is oversized for your heat demand
  • Ensure minimum flow rate is maintained
  • Check if hot water mode is enabled
  • Verify 3-way valve is switching to tank position
  • Check if immersion heater is working (if equipped)
  • Review hot water schedule settings
  • Tank sensor may need checking
  • Check and clean the system filter
  • Bleed air from the system
  • Check water pump operation
  • Inspect for blockages in pipes
  • Check system pressure
  • Check if the integration is active
  • If you added the integration using a guest account, check if you have granted all required permissions
  • Check that your heat pump controller is on the main screen - some heat pumps don't send data if you open a submenu and leave it there
  • After returning to the main screen on the controller, you may need to wait up to 24 hours for data to start flowing again
  • Check if there is data in the original manufacturer app - if not, your heat pump may not support this feature or may have a sensor misconfiguration

Ready to Monitor Your Heat Pump?

Start tracking all these parameters and optimize your heat pump's performance. Join thousands of users who are saving energy and extending their heat pump's lifespan.